<LOGO>
FM Transmitter Measurement Report
Created: 2025-09-20 16-09-11
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 61 dBuV VOLTAGE
Pilot RDS Phase Difference
6.5 kHz 4.3 kHz -12 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
12 kHz 71 kHz 3838 56,7223
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,2 dBr 7,49 dBr 8,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 16:09, 20.09.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (60 dBuV) Max at: 71 kHz MIN: 12 kHz % above 75 kHz: 56,7223 Acquired: 2025/09/20 16:08:07 Total samples: 3838 Equivalent time: 0:03:11 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 100 200
FM Scope MAX: 8,3 dBr MIN: 6,2 dBr AVE: 7,49 dBr % above 10,2 dBr: 0,0 Last value: 8,0 dBr (2025/09/20 16:08:06) Station: 96.90 MHz, signal: 4/5 (60 dBuV) 16:01 16:02 16:03 16:04 16:05 16:06 16:07 16:08 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality